Designed to anticipate future requirements and go beyond current standards, our test facility enables DC/AC and DC/DC converter testing, performance and efficiency analysis, as well as support for the development and optimization of control strategies.

Our Inverter Testing Expertise

Our teams carry out test campaigns tailored to the different development and validation stages of power converters and inverters:

  • DC/AC and DC/DC converters
  • Efficiency analysis (P, U, I)
  • Harmonic distortion measurement
  • Thermal management and mapping optimization, including the impact of the cooling system
  • Lifetime testing: WLTP and mission profiles
  • Electrical fault simulation: short circuit, AC or DC open circuit, overvoltage and undervoltage
  • Validation of hardware (power electronics) and software technology choices
  • Development of electric motor control strategies (speed/torque) and inverter control strategies (PWM)
  • Support for control strategy optimization and development, focusing on performance and safety
  • Benchmarking
  • Run-in testing / COP

These tests enable us to characterize the efficiency and behaviour of power converters under different operating conditions and identify opportunities to optimize their performance.

Our Inverter Testing Facilities

CRITT M2A provides a dedicated test environment capable of reproducing the electrical, thermal and operating conditions required for power converter characterization and validation.

  • BATTERY SIMULATOR

Our battery simulator supplies the power converter under a wide range of operating conditions:

– Power: up to 320 kW
– Voltage: up to 1,000 V
– Current: up to 800 A

  • CLIMATIC CHAMBER

Our climatic chamber enables equipment behaviour to be characterized under different environmental conditions:

– +90°C – 70°C
– 95% – 5%
xxxxx

  • Three-Phase Electric Motor Emulator

Our motor emulator reproduces the behaviour of an electric motor to test and characterize the power converter:

– Power: 320 kW (AC or DC)
– Voltage: up to 735 V phase-to-phase
– Current: up to 400 A per phase

 

 

  • Liquid Cooling System

Our liquid cooling system enables thermal conditions to be reproduced and controlled throughout the tests:

– Temperature down to -30°C
– Flow rate up to 20L/min– Débit massique : jusqu’à 20L/min
wwww
wwww

Our facilities provide high-frequency data acquisition up to 1 MHz for the main parameters required for system analysis (Voltage, current, speed and torque) AVL X-ion e-Power

Do You Have an Inverter Testing Project?

Efficiency characterization, mapping, thermal management, control strategy validation or electrical fault simulation: our teams support you in defining and carrying out a test campaign tailored to your power converter.

Contact our team to discuss your project and define the testing program that best meets your requirements.