Our technicians and engineers carry out you tests with 5 gas stands, dimensioned according to three standard sizes:
Tests of performance:
- Compressor map
- Turbine map
- Specific mapping
- Flow tests
- ...
Tests of qualification:
- Bearing system (shaft motion, marginal lubrification, ...)
- Burst and containment (turbine and compressor)
- Heat Soak Back (HSB)
- Axial load
- Blow-by measurements
- ...
Tests of durability:
- High and low cycles fatigue
- Hydrodynamism
- Thermal shock
- Hot temperature
- Creeping tests
- ...
We also propose further tests and specific analysis on turbochargers upstream and downstream parts:
- Exhaust manifold
- Exhaust line
- EGR cooler
More about our equipment here.
<< Back
|
|


|
|